Hi,

Can someone help me out. I use BODS version 14.1.1.210. I have setup the connection to BW source and imported metadata for my OpenHub - no problem.

Then created DTP and processchain to load Open hub data in BW.

Made dataflow in BODS with Open Hub Tables as source and maintained processchain to be executed. When executing BODS job I get the following error:

 

6800 10580 JOB 17-03-2014 13:10:34 Job <Test_OpenHub> is terminated due to error <170101>.

 

6800 10580 SYS-170101 17-03-2014 13:10:34 |Session Test_OpenHub|Data flow Test Openhub

6800 10580 SYS-170101 17-03-2014 13:10:34 System Exception <ACCESS_VIOLATION> occurred. Process dump option is off. Process is not dumped.

6800 10580 SYS-170101 17-03-2014 13:10:34 Call stack:

6800 10580 SYS-170101 17-03-2014 13:10:34 (null)

6800 10580 SYS-170101 17-03-2014 13:10:34 Registers:

6800 10580 SYS-170101 17-03-2014 13:10:34 RAX=00000000747E1648  RBX=0000000000209AB8  RCX=0000000000209AB8  RDX=0000000000000160  RSI=000000000231DAC0

6800 10580 SYS-170101 17-03-2014 13:10:34 RDI=0000000008BEBAC0  RBP=0000000000000000  RSP=00000000002099C0  RIP=000000007477730A  FLG=0000000000010206

6800 10580 SYS-170101 17-03-2014 13:10:34 R8=0000000000000000   R9=00000000FFFFFFFF  R10=0000000000620064  R11=0000000008C93600  R12=000000000033D390

6800 10580 SYS-170101 17-03-2014 13:10:34 R13=0000000081D6FEC0  R14=000000000020A008  R15=000000000020A030

6800 10580 SYS-170101 17-03-2014 13:10:34 Exception code: C0000005 ACCESS_VIOLATION

6800 10580 SYS-170101 17-03-2014 13:10:34 Fault address:  000000007477730A 01:000000000002630A

6800 10580 SYS-170101 17-03-2014 13:10:34 C:\Windows\WinSxS\amd64_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.4940_none_88df89932faf0bf6\MSVCP80.dll

6800 10580 SYS-170101 17-03-2014 13:10:34 ==========================================================

6800 10580 SYS-170101 17-03-2014 13:10:34 Collect the following and send to Customer Support:

6800 10580 SYS-170101 17-03-2014 13:10:34 1. Log files(error_*, monitor_*, trace_*) associated with this failed job.

6800 10580 SYS-170101 17-03-2014 13:10:34 2. Exported ATL file of this failed job.

6800 10580 SYS-170101 17-03-2014 13:10:34 3. DDL statements of tables referenced in this failed job.

6800 10580 SYS-170101 17-03-2014 13:10:34 4. Data to populate the tables referenced in the failed job. If not possible, get the last few rows (or sample of them) when

6800 10580 SYS-170101 17-03-2014 13:10:34 the job failed.

6800 10580 SYS-170101 17-03-2014 13:10:34 5. Core dump, if any, generated from this failed job.

6800 10580 SYS-170101 17-03-2014 13:10:34 ==========================================================

 

 

Any good ideas?